EN
Home Products ExPro
ATEX certified Zone 1 · 2 · 21 · 22

ExPro.

A family of probes and sensors: ExPro-C (temperature/humidity for ExCos-D) and ExPro-B (for ExBin-D) for Ex zones, their safe-area counterparts InPro-C/InPro-B for InCos-D/InBin-D, and the stand-alone thermal trigger ExPro-TT/InPro-TT for fire dampers.

4 familiesExPro-C/B and InPro-C/B (T/F/TF)
–40…+125 °Ctemperature range
0–100% rHhumidity range
50–200 mmprobe lengths
IP66protection rating
ExPro-C/B – probes in various lengths ATEX certification

Key features

  • ExPro-C: probe for the ExCos-D/RedCos-D transmitter (air temperature and/or humidity)
  • ExPro-B: probe for the ExBin-D/RedBin-D transmitter (temperature/humidity thermostat)
  • InPro-C / InPro-B: the same probes for the safe area (InCos-D / InBin-D)
  • All families in 3 versions: T (temperature only), F (humidity only), TF (combined)
  • 4 probe lengths: 50 / 100 / 150 / 200 mm, plug-in connector
  • Materials: adapter stainless steel 1.4305/PEEK, housing stainless steel 1.4301, cap AISI 316
  • ExPro-TT/InPro-TT: stand-alone thermal trigger for fire dampers (see below)

Applications

Air temperature Relative humidity Fire dampers (ExPro-TT/InPro-TT)
ExPro-C can only be used with ExCos-D/RedCos-D, ExPro-B only with ExBin-D/RedBin-D – always 1 probe per transmitter. The probes have no Ex marking of their own (certification is provided by the transmitter).

Technical data

ExPro-C / ExPro-B probe

Temperature range
–40…+125 °C (50 mm probe: –40…+80 °C); max. medium temperature depending on temperature class: T6 60 °C, T5 75 °C, T4 110 °C, T3–T1 125 °C
Humidity range
0–100% rH (humidity measurement only at temperatures above 0 °C; operation in non-condensing environment up to 95% rH)
Accuracy
±0.5–2.0 °C (depending on range/probe length) · ±4% rH (10–90% rH), ±5% rH outside this range
Probe lengths
50 / 100 / 150 / 200 mm
Response time
T90/20 s (temperature) · T90/4 s (humidity)
Materials
Adapter 1.4305/PEEK-GF30, housing 1.4301, cap AISI 316
Connection
Plug-in connector, max. 1 probe per transmitter
Ex-i parameters – ExPro-C
Ui=7.9 V, Pi=95 mW, Ii=48 mA
Ex-i parameters – ExPro-B
Ui=9.6 V, Ci=120 nF, Ii=9.7 mA

ExPro-TT (thermal trigger)

Operating temperature
Ta –40…+72 °C (ambient) / Tb –40…+55 °C
Protection rating
IP66
Weight
~200 g
Ex-i parameters
Ui=30 V, Ii=25 mA, Pi=60 mW

Environment

Protection rating
IP66 (except for the temperature/humidity sensing element itself – it must be exposed to the air)
Zone
1, 2, 21, 22

ExPro-C and ExPro-B (for Ex zones) and their safe-area counterparts InPro-C and InPro-B share the same design (the only difference is the paired transmitter); all families exist in 3 variants according to the measured quantity.

ExPro-C For ExCos-D / RedCos-D

Air temperature and/or humidity

VariantMeasuresProbe lengths
ExPro-CTTemperature50 / 100 / 150 / 200 mm
ExPro-CFHumidity50 / 100 / 150 / 200 mm
ExPro-CTFTemperature + humidity50 / 100 / 150 / 200 mm

ExPro-B For ExBin-D / RedBin-D

Temperature/humidity thermostat

VariantMeasuresProbe lengths
ExPro-BTTemperature50 / 100 / 150 / 200 mm
ExPro-BFHumidity50 / 100 / 150 / 200 mm
ExPro-BTFTemperature + humidity50 / 100 / 150 / 200 mm

InPro-C For InCos-D (safe area)

Air temperature and/or humidity – outside Ex zones

VariantMeasuresProbe lengths
InPro-CTTemperature50 / 100 / 150 / 200 mm
InPro-CFHumidity50 / 100 / 150 / 200 mm
InPro-CTFTemperature + humidity50 / 100 / 150 / 200 mm

InPro-B For InBin-D (safe area)

Temperature/humidity thermostat – outside Ex zones

VariantMeasuresProbe lengths
InPro-BTTemperature50 / 100 / 150 / 200 mm
InPro-BFHumidity50 / 100 / 150 / 200 mm
InPro-BTFTemperature + humidity50 / 100 / 150 / 200 mm

ExPro-TT / InPro-TT Accessory – ExPro-TT for ExMax/RedMax-BF, InPro-TT for InMax-BF

Thermal trigger for fire dampers – not a probe for a transmitter

ModelLengthTrigger temperatureNote
ExPro-TT-72 / InPro-TT-7265 mmTf1 +72 °C (ambient) / Tf2 +71 °C (duct)ExPro-TT → ExMax/RedMax-BF; InPro-TT → InMax-BF
ExPro-TT-72-L90 / InPro-TT-72-L9090 mmTf1 +72 °C / Tf2 +71 °CExPro-TT → ExMax/RedMax-BF; InPro-TT → InMax-BF
Special versions to order: ExPro-TT-...-S1 (Ex-e cable gland M25×1.5 mm instead of the standard M12) and ExPro-TT-...-S6 (extended 1.5 m cable).
ExPro-TT is exclusively an accessory for ExMax-...-BF and RedMax-...-BF actuators, InPro-TT exclusively for InMax-...-BF actuators (see the ExMax page) – power is supplied only by a -BF type actuator; it does not work on its own. It is not a probe for ExCos-D or ExBin-D.

Designation key

What the suffixes mean

C vs. B

C = for ExCos-D (modulating transmitter), B = for ExBin-D (switching thermostat).

Ex vs. In

Ex = for Ex zones (1, 2, 21, 22), In = the same probe for the safe (non-Ex) area, for InCos-D/InBin-D transmitters.

T / F / TF

T = temperature only, F = humidity only (Feuchte), TF = both combined.

TT

Temperature Trigger – thermal trigger for fire dampers: ExPro-TT exclusively for ExMax/RedMax-BF, InPro-TT exclusively for InMax-BF.

ExPro-TT – Ex ia IIC T6 Gb

EPS 19 ATEX 1 020

European certification for explosive gas atmospheres. The thermal trigger’s own certificate.

Zone 1 Zone 2

ExPro-TT – Ex tb IIIC T80 °C Db

EPS 19 ATEX 1 020

Certification for dust atmospheres, max. surface temperature 80 °C.

Zone 21 Zone 22

ExPro-TT – IECEx

IECEx EPS 19.0012

International IECEx certification. Also CSA Class II Div.1 Groups EFG T80 °C Db and Class I Zone 1 AEx ia IIC T6 Gb for the North American market.

ExPro-C / ExPro-B – production quality

BVS ATEX ZQS/E136

C/B probes have no type certificate of their own – intrinsic safety and Ex marking are ensured by the connected ExCos-D/ExBin-D transmitter. The manufacturer has a certified production quality system (DEKRA).

Datasheets